Namrata Power Systems
Namrata Power Systems
Guruwar Peth, Pune, Maharashtra
GST No. 27AAHFN4728M1ZS
TrustSEAL Verified
Call 0804605801588% Response Rate
SEND EMAIL

Emerson Vertiv Hipulse Online UPS

Leading Wholesale Distributor of emerson liebert hipulse-u 30kva three phase online ups, emerson liebert 200 kva hipulse-u three phase online ups, emerson liebert hipulse-u 40 kva three phase online ups and emerson liebert hipulse-u 160kva three phase online ups from Pune.

Emerson Liebert Hipulse-U 30KVA Three Phase Online UPS

Emerson Liebert Hipulse-U 30KVA Three Phase Online UPS
  • Emerson Liebert Hipulse-U 30KVA Three Phase Online UPS
Get Best Quote
Approx. Price: Rs 4.63 Lakh / UnitGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Unit
Model Name/NumberLIEBERT HIPULSE-U
BrandEmerson Vertiv
Input Voltage380/400/415 VAC 3-W Plus Ground
Capacity30KVA
Output Voltage380/400/415 VAC 3-W Plus Ground
Configuration3 Phase IN - 3 Phase OUT
Battery TypeSMF
PhaseThree Phase
ProtectionOvervoltage, OverCurrent, Overload, ShortCircuit
Efficiency93%
TypeOnline UPS
Warranty1 Year
Operating Temperature0 to 40 Deg. C
Form FactorTower Model
Power Cord LengthPower cord not Provided. Terminal block provided
Frequency50 HZ
Audible Noise55 dbA
DimensionD 810 x W 715 x H 1615 ( in mm)
Display TypeLCD Display and mimic panel
Weight530Kg
Humidity0-95 % Non condensing
Back Up Time120-150mins
Storage Temperature0-55 Deg.C
Battery Backup2-2.5 hrs
AlarmYes
Battery RatingExternal 12 V 200 AH 34 Nos
Mounting TypeTower
Charging Current20A
Number Of Batteries Supported34 Nos
Recharge Time10-12 hrs to 90% of battery AH Capacity
Wave TypePure since wave
Supported Battery TypesSMF
Maximum Charging Current20 AMP
Transfer Time0 ms
Change Over Time0 ms
Battery Voltage408 VDC
Transient Recovery20 millisecond to 1%
Input AVR Range290 to 498 VAC
Short Circuit ProtectionYes
WaveformPure sine wave
Noise Level55 dBA
TopologyDouble conversion Online UPS
Crest Factor3:1
Emc StandardIEC 62040-2
Operating Temp Deg Celsius0-40 Deg. C at Rated capacity 40-50 Deg. C UPS capacity linearly de-rated
Output WaveformPure sinewave
Overload101-110% 60 mins,111-125% -10 mins,125-150% - 1 mins
Parallel ConfigurationYes
Performance StandardDesign & Method - IEC 62040-3
Safety StandardIEC 62040 -1-1
Voltage TolerancesWide input voltage Tolerance - +20% to -20%
Dc Voltage408 VDC
Frequency Range50 Hz (45HZ TO 65HZ)
Thd - Linear Load3%
Short CircuitYes
I Deal InNew Only
Usage/ApplicationLaser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS
Country of OriginMade in India
Input And Output Voltage300/400/415 VAC 3-W Plus Ground
Input Frequency45-55 Hz
Power FactorInput p.f. 0.9 (with optional filter)
Permissible Load Unbalance100%
Non Linear Load Capability100%

The Liebert Hipulse-U UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-UTM offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.
Features:
Fully Digital, twin DSP controlled.
Rated at 0.9 output power factor to deliver more active power.
Handle leading power factor loads without KW derating under specified conditions.
On-Line Double Conversion IGBTbased PWM Inverter.
Wide input voltage tolerance (+20/-20%).
Wide input frequency range of 45Hz to 65Hz.
High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds).
Built-in maintenance bypass Front access for spares replacement and preventive maintenance.
Easy Dual bus configuration architecture.
Built Investment Protection:
Automatic battery testing
Field settability of EOD of the battery
Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)
Protection against deep discharge of battery
Battery circuit breaker instead of using AC isolator
Short-circuit proof inverter
Back-feed protection
D-level lightning protection
With 3 auxiliary power supply to ensure redundancy under any condition
Standard dry contacts
Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
Choice of array of input harmonic filter options
Compatible with LiebereActiye Harmonic Filter Temperature-compensated battery charging (optional)

Request
Callback


Additional Information:

  • Delivery Time: 4-5 Weeks / As per stock availability in Emerson after confirm PO
Yes! I am interested

Emerson Liebert 200 Kva Hipulse-U Three Phase Online Ups

Emerson Liebert 200 Kva Hipulse-U Three Phase Online Ups
  • Emerson Liebert 200 Kva Hipulse-U Three Phase Online Ups
Get Best Quote
Approx. Price: Rs 15.5 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandEmerson Vertiv
Model Name/NumberLIEBERT HIPULSE-U
Capacity200 KVA
Input Voltage380/400/415 VAC 3-W Plus Ground
Output Voltage380/400/415 VAC 3-W Plus Ground
Configuration3 Phase IN - 3 Phase OUT
Form FactorTower Model
Audible Noise<65 dBA
TopologyDouble conversion Online UPS
Crest Factor3:1
Emc StandardIEC 62040-2
Output WaveformPure sinewave
Overload101-110% 60 mins, 111-125% -10 mins, 125-150% - 1 mins
Parallel ConfigurationYes
Performance StandardDesign & Method - IEC 62040-3
Safety StandardIEC 62040 -1-1
Voltage TolerancesWide input voltage Tolerance - +20% to -20%
Usage/ApplicationLaser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS
Country of OriginMade in India

The Liebert Hipulse-U UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-UTM offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.
Features:
Fully Digital, twin DSP controlled.
Rated at 0.9 output power factor to deliver more active power.
Handle leading power factor loads without KW derating under specified conditions.
On-Line Double Conversion IGBTbased PWM Inverter.
Wide input voltage tolerance (+20/-20%).
Wide input frequency range of 45Hz to 65Hz.
High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds).
Built-in maintenance bypass Front access for spares replacement and preventive maintenance.
Easy Dual bus configuration architecture.
Built Investment Protection:
Automatic battery testing
Field settability of EOD of the battery
Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)
Protection against deep discharge of battery
Battery circuit breaker instead of using AC isolator
Short-circuit proof inverter
Back-feed protection
D-level lightning protection
With 3 auxiliary power supply to ensure redundancy under any condition
Standard dry contacts
Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
Choice of array of input harmonic filter options
Compatible with LiebereActiye Harmonic Filter Temperature-compensated battery charging (optional)
Request
Callback
Yes! I am interested

Emerson Liebert Hipulse-U 40 KVA Three Phase Online Ups

Emerson Liebert Hipulse-U 40 KVA  Three Phase Online Ups
  • Emerson Liebert Hipulse-U 40 KVA  Three Phase Online Ups
Get Best Quote
Approx. Price: Rs 5.2 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandEmerson Vertiv
Model Name/NumberLIEBERT HIPULSE-U
Capacity40KVA
Input Voltage380/400/415 VAC 3-W Plus Ground
Output Voltage380/400/415 VAC 3-W Plus Ground
Configuration3 Phase IN - 3 Phase OUT
Efficiency93%
Form FactorTower Model
Power Cord LengthPower cord not Provided. Terminal block provided
Audible Noise55 dBA
DimensionD 810 x W 715 x H 1615 ( in mm)
Display TypeLCD Display and mimic panel
Weight530 Kg
Back Up Time180 mins
Storage Temperature0-55 Deg.C
Battery Backup3 Hrs
Battery RatingEXTERNAL 12 V 2*150 AH 34 NOS
Charging Current30A
Number Of Batteries Supported34 Nos
Recharge Time10-12 hrs to 90% of battery AH Capacity
Supported Battery TypesSMF
Transfer Time0 ms
Transient Recovery20 millisecond to 1%
WaveformPure sine wave
Noise Level55 dBA
TopologyDouble conversion Online UPS
Crest Factor3:1
Emc StandardIEC 62040-2
Operating Temp Deg Celsius0-40 Deg. C at Rated capacity 40-50 Deg. C UPS capacity linearly de-rated
Output WaveformPure sinewave
Overload101-110% 60 mins, 111-125% -10 mins, 125-150% - 1 mins
Parallel ConfigurationYes
Performance StandardDesign & Method - IEC 62040-3
Safety StandardIEC 62040 -1-1
Voltage TolerancesWide input voltage Tolerance - +20% to -20%
Dc Voltage408 VDC
Frequency Range50 Hz (45HZ TO 65HZ)
Thd - Linear Load3%
Short CircuitYes
I Deal InNew Only
Usage/ApplicationLaser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS
Country of OriginMade in India

The Liebert Hipulse-U UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-UTM offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.
Features:
Fully Digital, twin DSP controlled.
Rated at 0.9 output power factor to deliver more active power.
Handle leading power factor loads without KW derating under specified conditions.
On-Line Double Conversion IGBTbased PWM Inverter.
Wide input voltage tolerance (+20/-20%).
Wide input frequency range of 45Hz to 65Hz.
High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds).
Built-in maintenance bypass Front access for spares replacement and preventive maintenance.
Easy Dual bus configuration architecture.
Built Investment Protection:
Automatic battery testing
Field settability of EOD of the battery
Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)
Protection against deep discharge of battery
Battery circuit breaker instead of using AC isolator
Short-circuit proof inverter
Back-feed protection
D-level lightning protection
With 3 auxiliary power supply to ensure redundancy under any condition
Standard dry contacts
Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
Choice of array of input harmonic filter options
Compatible with LiebereActiye Harmonic Filter Temperature-compensated battery charging (optional)

Request
Callback
Yes! I am interested

Emerson Liebert Hipulse-U 160KVA Three Phase Online UPS

Emerson Liebert Hipulse-U 160KVA Three Phase Online UPS
  • Emerson Liebert Hipulse-U 160KVA Three Phase Online UPS
Get Best Quote
Approx. Price: Rs 11.25 Lakh / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
BrandEmerson Vertiv
Model Name/NumberLIEBERT HIPULSE-U
Capacity160 KVA
Input Voltage380/400/415 VAC 3-W Plus Ground
Configuration3 Phase IN - 3 Phase OUT
Efficiency93%
Form FactorTower Model
Power Cord LengthPower cord not Provided. Terminal block provided
Usage/ApplicationLaser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS
Country of OriginMade in India

The Liebert Hipulse-U UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-UTM offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.
Features:
Fully Digital, twin DSP controlled.
Rated at 0.9 output power factor to deliver more active power.
Handle leading power factor loads without KW derating under specified conditions.
On-Line Double Conversion IGBTbased PWM Inverter.
Wide input voltage tolerance (+20/-20%).
Wide input frequency range of 45Hz to 65Hz.
High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds).
Built-in maintenance bypass Front access for spares replacement and preventive maintenance.
Easy Dual bus configuration architecture.
Built Investment Protection:
Automatic battery testing
Field settability of EOD of the battery
Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)
Protection against deep discharge of battery
Battery circuit breaker instead of using AC isolator
Short-circuit proof inverter
Back-feed protection
D-level lightning protection
With 3 auxiliary power supply to ensure redundancy under any condition
Standard dry contacts
Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
Choice of array of input harmonic filter options
Compatible with LiebereActiye Harmonic Filter Temperature-compensated battery charging (optional)
Request
Callback
Yes! I am interested
X

Explore More Product

View All Product


Reach Us
Nilesh Sancheti (Partner)
Namrata Power Systems
Office No. 104, S. No. 141, Shubh Vastu Building
Guruwar Peth, Pune - 411042, Maharashtra, India


Call Us


Send E-mail