Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | LIEBERT HIPULSE-U |
Brand | Emerson Vertiv |
Capacity | 30KVA |
Input Voltage | 380/400/415 VAC 3-W Plus Ground |
Output Voltage | 380/400/415 VAC 3-W Plus Ground |
Configuration | 3 Phase IN - 3 Phase OUT |
Battery Type | SMF |
Phase | Three Phase |
Protection | Overvoltage, OverCurrent, Overload, ShortCircuit |
Efficiency | 93% |
Type | Online UPS |
Warranty | 1 Year |
Operating Temperature | 0 to 40 Deg. C |
Form Factor | Tower Model |
Power Cord Length | Power cord not Provided. Terminal block provided |
Frequency | 50 HZ |
Audible Noise | 55 dbA |
Dimension | D 810 x W 715 x H 1615 ( in mm) |
Display Type | LCD Display and mimic panel |
Weight | 530Kg |
Humidity | 0-95 % Non condensing |
Back Up Time | 120-150mins |
Storage Temperature | 0-55 Deg.C |
Battery Backup | 2-2.5 hrs |
Alarm | Yes |
Battery Rating | External 12 V 200 AH 34 Nos |
Mounting Type | Tower |
Charging Current | 20A |
Number Of Batteries Supported | 34 Nos |
Wave Type | Pure since wave |
Recharge Time | 10-12 hrs to 90% of battery AH Capacity |
Supported Battery Types | SMF |
Maximum Charging Current | 20 AMP |
Change Over Time | 0 ms |
Transfer Time | 0 ms |
Battery Voltage | 408 VDC |
Input AVR Range | 290 to 498 VAC |
Transient Recovery | 20 millisecond to 1% |
Short Circuit Protection | Yes |
Waveform | Pure sine wave |
Noise Level | 55 dBA |
Topology | Double conversion Online UPS |
Crest Factor | 3:1 |
Emc Standard | IEC 62040-2 |
Operating Temp Deg Celsius | 0-40 Deg. C at Rated capacity 40-50 Deg. C UPS capacity linearly de-rated |
Output Waveform | Pure sinewave |
Overload | 101-110% 60 mins,111-125% -10 mins,125-150% - 1 mins |
Parallel Configuration | Yes |
Performance Standard | Design & Method - IEC 62040-3 |
Safety Standard | IEC 62040 -1-1 |
Voltage Tolerances | Wide input voltage Tolerance - +20% to -20% |
Dc Voltage | 408 VDC |
Frequency Range | 50 Hz (45HZ TO 65HZ) |
Thd - Linear Load | 3% |
Short Circuit | Yes |
I Deal In | New Only |
Usage/Application | Laser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS |
Country of Origin | Made in India |
Input And Output Voltage | 300/400/415 VAC 3-W Plus Ground |
Input Frequency | 45-55 Hz |
Power Factor | Input p.f. 0.9 (with optional filter) |
Permissible Load Unbalance | 100% |
Non Linear Load Capability | 100% |
The Liebert Hipulse-U UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. The Liebert Hipulse-UTM offers protection to your investment, and provide lower cost of ownership through its digital architecture and range of options which you can customize specifically for your needs.
Features:
Fully Digital, twin DSP controlled.
Rated at 0.9 output power factor to deliver more active power.
Handle leading power factor loads without KW derating under specified conditions.
On-Line Double Conversion IGBTbased PWM Inverter.
Wide input voltage tolerance (+20/-20%).
Wide input frequency range of 45Hz to 65Hz.
High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds).
Built-in maintenance bypass Front access for spares replacement and preventive maintenance.
Easy Dual bus configuration architecture.
Built Investment Protection:
Automatic battery testing
Field settability of EOD of the battery
Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour)
Protection against deep discharge of battery
Battery circuit breaker instead of using AC isolator
Short-circuit proof inverter
Back-feed protection
D-level lightning protection
With 3 auxiliary power supply to ensure redundancy under any condition
Standard dry contacts
Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
Choice of array of input harmonic filter options
Compatible with LiebereActiye Harmonic Filter Temperature-compensated battery charging (optional)
SCR Based Rectifier
IGBT based inverter
True online Double conversion Online UPS
Industrial grade online UPS Systems
Emerson / Vertiv make
Using in industry for laser cutting machine, IT Load, Hospital load
Three phase - Three phase Online UPS
Keyword:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Emerson Vertiv |
Model Name/Number | LIEBERT HIPULSE-U |
Capacity | 200 KVA |
Input Voltage | 380/400/415 VAC 3-W Plus Ground |
Output Voltage | 380/400/415 VAC 3-W Plus Ground |
Configuration | 3 Phase IN - 3 Phase OUT |
Form Factor | Tower Model |
Audible Noise | <65 dBA |
Topology | Double conversion Online UPS |
Crest Factor | 3:1 |
Emc Standard | IEC 62040-2 |
Output Waveform | Pure sinewave |
Overload | 101-110% 60 mins,111-125% -10 mins,125-150% - 1 mins |
Parallel Configuration | Yes |
Performance Standard | Design & Method - IEC 62040-3 |
Safety Standard | IEC 62040 -1-1 |
Voltage Tolerances | Wide input voltage Tolerance - +20% to -20% |
Usage/Application | Laser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS |
Country of Origin | Made in India |
Keyword:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Emerson Vertiv |
Model Name/Number | LIEBERT HIPULSE-U |
Capacity | 160 KVA |
Input Voltage | 380/400/415 VAC 3-W Plus Ground |
Configuration | 3 Phase IN - 3 Phase OUT |
Efficiency | 93% |
Form Factor | Tower Model |
Power Cord Length | Power cord not Provided. Terminal block provided |
Usage/Application | Laser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS |
Country of Origin | Made in India |
Keyword:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Emerson Vertiv |
Model Name/Number | LIEBERT HIPULSE-U |
Capacity | 40KVA |
Input Voltage | 380/400/415 VAC 3-W Plus Ground |
Output Voltage | 380/400/415 VAC 3-W Plus Ground |
Configuration | 3 Phase IN - 3 Phase OUT |
Efficiency | 93% |
Form Factor | Tower Model |
Power Cord Length | Power cord not Provided. Terminal block provided |
Audible Noise | 55 dBA |
Dimension | D 810 x W 715 x H 1615 ( in mm) |
Display Type | LCD Display and mimic panel |
Weight | 530 Kg |
Back Up Time | 180 mins |
Storage Temperature | 0-55 Deg.C |
Battery Backup | 3 Hrs |
Battery Rating | EXTERNAL 12 V 2*150 AH 34 NOS |
Charging Current | 30A |
Number Of Batteries Supported | 34 Nos |
Recharge Time | 10-12 hrs to 90% of battery AH Capacity |
Supported Battery Types | SMF |
Transfer Time | 0 ms |
Transient Recovery | 20 millisecond to 1% |
Waveform | Pure sine wave |
Noise Level | 55 dBA |
Topology | Double conversion Online UPS |
Crest Factor | 3:1 |
Emc Standard | IEC 62040-2 |
Operating Temp Deg Celsius | 0-40 Deg. C at Rated capacity 40-50 Deg. C UPS capacity linearly de-rated |
Output Waveform | Pure sinewave |
Overload | 101-110% 60 mins,111-125% -10 mins,125-150% - 1 mins |
Parallel Configuration | Yes |
Performance Standard | Design & Method - IEC 62040-3 |
Safety Standard | IEC 62040 -1-1 |
Voltage Tolerances | Wide input voltage Tolerance - +20% to -20% |
Dc Voltage | 408 VDC |
Frequency Range | 50 Hz (45HZ TO 65HZ) |
Thd - Linear Load | 3% |
Short Circuit | Yes |
I Deal In | New Only |
Usage/Application | Laser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS |
Country of Origin | Made in India |
Keyword: